pH/ORP Sensor
PCPR1K/PCPR100

  • Type: Combination pH Sensor for Waste water applications.
  • Material: Ryton Body.
  • Temperature Range: 0 – 150 °C.
  • Temp Element: Pt 100/ Pt 1000.
  • Accuracy: + / - 0.2 pH.
  • Pressure Limit: 0 - 100psig @ 100°C (0-6.9 bar @ 100°C).

Read More

pH/ORP Sensor
PCPDR1K/PCPDR100

  • Type: Differential pH Sensor for designed Special applications.
  • Material: Ryton Body.
  • Temperature Range: 0 – 95 °C.
  • Temp Element: Pt100 / Pt 1000.
  • Pressure Limit: 0 - 100psig @95 °C (0 - 6.9bar @ 95 °C).
  • Measuring Range: 0 -14 pH.

Read More

pH/ORP Transmitters
PC 2000

  • Measurement: pH/ORP or Conductivity or Total Dissolved Solids (TDS). 
  • Power Requirements: 100 – 270V AC ±10%, 50/60 Hz. 
  • Display: Graphic LCD with Backlit display.
  • Operating Conditions: Temperature: 0 - 65°C, RH – 0-95% Non-condensing. 
  • Analog Output Signal: 2. 4-20 mA isolated current outputs, max 600Ω.

Read More

pH/ORP Transmitters
PC100

  • Measurement: pH or ORP. 
  • Power Requirements: 12 to 24V DC.
  • Display: 7 Segment. 
  • Operating Conditions: Temperature: -10°C to 110°C.
  • Analog Output Signal: 4 to 20Ma Isolated Current Output; max 600 Ω.

Read More

pH Sensor
PCPHP

  • Type: Combination pH Sensor for High Purity applications.
  •  Material: Durable Ultem Body
  • Temperature Range: 0 - 100 °C.
  • Temp Element: Pt 100/ Pt 1000.
  • Response Time: 95% in 1 second.
  • Glass shape: Bulb.

Read More

pH Sensor
PCVR100_HT

  • Type: Combination pH Sensor for High-Temperature Applications.
  •  Material: Kynar Body.
  • Temperature Element: Pt 100/ Pt 1000.
  • Temperature Range: 0 - 130 °C.
  • Accuracy: +/- 0.03 pH.
  • Pressure Limit: 100 psig.

Read More

pH Sensor
PCVR100_SP

  • Type: Combination Sensor for Harsh/ Applications.
  • Material: Ryton Body.
  • Temperature Element: Pt 100/ Pt 1000.
  • Temperature Range: 0 - 100 °C.
  • Accuracy: +/- 0.03 pH.
  • Pressure Limit: 100 psig.

Read More

pH/ORP Transmitters
PC 1000

  • Measurement: pH/ORP or Conductivity or Total Dissolved Solids (TDS). 
  • Power Requirements: 100 – 270V AC ±10%, 50/60 Hz.
  • Display: Graphic LCD with Backlit display.
  • Operating Conditions: Temp: 0 - 65°C, RH – 0-95% Non-condensing. 
  • Analog Output Signal: 2. 4-20 mA isolated current outputs, max 600Ω.

Read More

pH/ORP Transmitters
PC100P

  • Measurement: pH and Temperature.
  • Power Requirements: 100-270V AC; 50 Hz.
  • Display: OLED 2*16 Alphanumeric.
  • Measuring Range Temperature: -15°C to 150°C.
  • Analog Outputs Signal: 4 to 20Ma Isolated Current Output; max 600 Ω.

Read More

pH/ORP Transmitters
PCPH105

  • Measurement: pH or ORP.
  • Power Requirements: 19-48V DC, Regulated, 30mA max.
  • Display: Dual LCD Display 128*65 dot matrix.
  • Operating Conditions: Temperature: -15 to 80°C, (5°F to 176°F).
  • Analog Output Signal: 4 to 20Ma Isolated Current Output; Max load 250 Ω @ 24V, 600 Ω@ 31V, 1500 Ω @48V.

Read More