Aluminum Analyzer
Micromac C

  • Measuring Principle: Colorimetric, Eriochromocyanine method, adicic dissolution of aluminium flocs.
  • Measuring Range: 0 - 0.5 / 0.7 / 1 / 3 / 5 ppm Al2+, other ranges available on request.
  • Measuring Time: 10 Minutes.
  • Sample Temperature: 10 °C – 30 °C.
  • Repeatability: better than 2 %.
  • Protection: IP 55.
  • Easy operation; plug in Analyzer, no special training is required.

Read More

Boron Analyzer
Micromac C

  • Measuring Principle: Colorimetric, azomethyne H
  • Measuring Range: 0 – 2 up to 50 ppm B; other ranges available on request.
  • Measuring Time: 35 Minutes.
  • Sample Temperature: 10 °C – 30 °C.
  • Repeatability: better than 2 %.
  • Protection: IP 55.
  • Easy operation; plug in Analyzer, no special training is required.

Read More

Calcium Analyzer
Micromac C

  • Measuring Principle: Colorimetric, blue methylthymol/ethanolammine
  • Measuring Range: 0 – 5 up to 300 ppm Ca2+; other ranges available on request.
  • Measuring Time: 10 Minutes.
  • Sample Temperature: 10 °C – 30 °C.
  • Repeatability: better than 2 %.
  • Protection: IP 55.
  • Easy operation; plug in Analyzer, no special training is required.

Read More

Copper Analyzer
Micromac C

  • Measuring Principle: Colorimetric, bathocuproine.
  • Measuring Range: 0 – 0.1 up to 20 ppm Cu; other ranges available on request.
  • Measuring Time: 10 - 12 Minutes.
  • Sample Temperature: 10 °C – 30 °C.
  • Repeatability: better than 2 %.
  • Protection: IP 55.
  • Easy operation; plug in Analyzer, no special training is required.

Read More

Cyanide Analyzer
Micromac C

  • Measuring Principle: Colorimetric, pyridine/barbituric acid.
  • Measuring Range: 0 – 0.5 up to 300 ppm as CN; other ranges available on request.
  • Measuring Time: 8 - 10 Minutes.
  • Sample Temperature: 10 °C – 30 °C.
  • Repeatability: better than 2 %.
  • Protection: IP 55.
  • Easy operation; plug in Analyzer, no special training is required.

Read More

Hydrazine Analyzer
Digox 6.1 HY-S

  • Measuring Range: 0 -1,000 ug/L N2H4.
  • Measurement Error: <1% in the measuring range 0-1000 ug/l or ± 3 µg/l in the range 0- 100 µg/L.
  • Resolution 0.1ug/L
  • Response Time: t90 < 8s.
  • Sample Temperature:0 - 60 °C, automatically compensated.

Read More

Hydrogen Analyzer
Digox 6.1 H2 -S

  • Measuring Range:0-100 cc/kg respectively 0-10mg/l dissolved H2.
  • Accuracy: <17cc/kg: 5 % reading or ± 1 cc/kg >17cc/kg: 10 % reading or ± 1 cc/kg.
  • Resolution 0,01 cc/kg, selectable.
  • Response Time: t80 < 20min.
  • Sample Temperature:15 - 45 °C, automatically compensated.

Read More

Nickel Analyzer
Micromac C

  • Measuring Principle: Colorimetric, bathocuproine.
  • Measuring Range: 0 – 0.1 up to 20 ppm Cu.
  • Detection Limit: Typically better 2% of the full scale.
  • Repeatability: better than 2%
  • Sample and waste delivery: 10 - 30°C
  • Protection: IP 55.
  • Easy operation; plug in Analyzer, no special training is required.

Read More