Pure Gas Analytics

Programmable Gas Analyser

  • Industry : Process
  • Gas : Oxygen, Moisture, Binary mixtures
  • Application : Gas Cylinder Analysis, Industrial Gas
  • Measurement range : ppm and %
  • Measuring cell type : Electrochemical, Paramagnetic, Zirconia, P2O5, Thermal Conductivity
  • Test Cylinder Pressure : 2-250 barg (15-3700 PSI) regulated
  • Gas Fittings : 1/8 in Swagelok® (supplied)

Downloads

SYSTECH

Gas Cylinder analysis system

  • Gas : Oxygen, Carbon Dioxide, Binary mixtures
  • Application : Industrial Gas, Welding, Glove Boxes
  • Technology : Thermal conductivity
  • Measurement range : ppm and %. Dependent on selected gas mix. Adjustable, auto-ranging. Typical 0-1000ppm (H2 in N2) 98-100% (O2 in Ar)
  • Suitable gases : Hydrogen, helium, oxygen, carbon dioxide, methane, carbon monoxide, argon, nitrogen and many others
  • Ingress protection : IP40

Download

SYSTECH

MM300

  • Application : Industrial Gas, Intrinsically Safe
  • Measurement range : -100°C to +20°C (-148°F to 68°F) Dew Point
  • Technology : Aluminium oxide
  • Accuracy : ±2°C (±3.6°F) Dew Point
  • Response Time : 90% of reading (T95) less than 5 minutes (dry to wet)
  • Ingress Protection : IP66, Nema 4X

SYSTECH

MM400

  • Application : Industrial Gas, Intrinsically Safe
  • Measurement range : Autoranging from -100°C to +20°C (-148°F to 68°F) and equivalent in ppm(v) moisture
  • Technology : Aluminium oxide
  • Accuracy : ±1°C from -60°C to +20°C. ±2°C from -100°C to -60°C
  • Response Time : Wet gas to dry gas: -20°C to -60°C, less than 60 seconds. Dry gas to wet gas: -100°C to -20°C, less than 60 seconds

SYSTECH

MM500

  • Application : Industrial Gas, Medical Gas Analysis, Welding
  • Technology : Phosphorus Pentoxide
  • Measurement range : Autoranging from 0.01ppm to 1000ppm and equivalent in dew point
  • Accuracy : ±5% of reading or 0.4 ppm(v)
  • Response Time : 90% within 60 seconds
  • Acceptable gases : Chlorine / HCI and other corrosive gases

SYSTECH MM500

SYSTECH MM500 Corrosive

EC900 (Electrochemical )

  • Application : Industrial Gas, Glove Boxes
  • Measuring cell type : Electrochemical: Percentage, trace and RACE™ cell (US & UK patents)
  • Measurement range : Trace 0.1ppm – 1%. RACE™ 0.1ppm – 30%. Percent 0.3% – 100%
  • Response Time : Trace 90% within 30 sec. RACE™ Air to 20ppm within 2 min. Percent 90% within 30 sec.
  • Unsuitable gases : Acid gases, corrosives and solvents in significant concentration

SYSTECH

EC91/92 (Electrochemical )

  • Application : Industrial Gas, Intrinsically Safe, Oxygen Deficiency
  • Measurement range : ppm and %
  • Technology : Electrochemical
  • Measurement range : 6 selectable: 0-20, 0-200, 0-2000 (ppm), 0-2%, 0-20%, 0-30%. Other ranges available on request.
  • Response Time : 90% of reading within 20 seconds
  • Ingress Protection : IP66, Nema 4X

SYSTECH EC92

SYSTECH EC91

EC96 (Electrochemical)

  • Application : Oxygen Deficiency
  • Measurement range : 0-30%
  • Technology : Electrochemical
  • Accuracy : ±0.1%
  • Response Time : 90% of reading within 20 seconds
  • Ingress protection : IP67 / Nema 4X

SYSTECH

PM700 (Paramagnetic)

  • Application : Industrial Gas, Medical Gas Analysis
  • Measurement range : Autoranging from 0.01 to 100% Oxygen
  • Technology : Paramagnetic
  • Response Time : 90% of reading (T90) less than 6 seconds
  • Explosive gas mixtures : Use the Ex-Proof Sensor Housing for explosive gas mixtures such as H2, Butane, CO, H2S

SYSTECH

ZR800 (Zirconia)

  • Application : Industrial Gas, Ovens/Furnaces, Welding
  • Measurement range : Autoranging from 0.1ppm to 100%
  • Technology : Zirconia
  • Response Time : 90% of step change within 5 seconds
  • Measuring cell type : Stabilised zirconia sensor

SYSTECH