All for Joomla All for Webmasters

ONLINE ANALYSER

Ammonia

  •  Colorimetric, phenate measurement method
  • Measuring time of 8 minutes
  • 0-0.2/0.7/2/5/10/20/100 ppm N-NH3, other ranges available on request
  • IP55 Protection
  • Integrated keyboard and graphics display, RS232 option
  • Dimension:800x450x300 mm(hxwxd)

ABB

SYSTEA

Ammonia Total

  • Colorimetric, Berthelot reaction Measurement Method
  • Measuring time of 20-25 minutes.
  • 0-2 up to 5 ppm
  • IP55 Protection
  • Integrated keyboard and graphics display, RS232 option
  • Dimension: 800x450x300 mm (hxwxd)

ABB

SYSTEA

Chlorine

• Amperometric  Free Chlorine Sensors
• Range 0 to 20 ppm (mg/L)
• 4 – 20 mA O/P
• NEMA 4X (with output wire glands sealed)

GF

ABB

Chloride

• Colorimetric Type
• Range 0 – 100 up to 500 mg/L as Cl- ; other ranges available on request
• 4-20 mA, RS232  Output
• IP55

SYSTEA

Chlorine Dioxide

• Amperometric Analysis
• Range 0 to 2 ppm (mg/L) as Chlorine Dioxide
• 4-20 mA Output
• IP-NEMA 4X

SYSTEA

COD/BOD/TSS/pH

  • 8″Colour touch screen
  • Fully automatic operation
  • Long autonomy, low maintenance, low operating cost
  • Nearly no reagents
  • Easy operation, fully documented plug in analyzer, No special training is required
  • Electronics and hydraulics completely separated
  • Serial interface for PC or printer connection (optional)

SYSTEA

Degassed Conductivity

  • Degassing and measurement at normal temperature
  • No heating up, therefore no gas emissions of other volatile acids
  • No inert gas required, air-conditioning by means of a molecular sieve
  • High gain of degassed carbonic acid
  • Interpolation of measuring results to actual CO2 content
  • Automatic shut down of the DAC reactor following the fall below the acceptable limit of 0.2 μS cm-1 (VGB-guideline)
  • Short response times
  • Regenerative operating chemicals

Dr Thiedig

Dissolved Oxygen (Aeration)

•Measuring range:0 to 20,000 ppb
•Units of measure:ppb, μg/l, μg/kg
•Accuracy:±5 % of reading or ±1 ppb, whichever is the greater
•Resolution:0.1 ppb
•Temperature compensation:5 to 55 °C (41 to 131 °F) automatic using a   Pt1000
•Salinity correction:Preset within the range 0 to 80 ppt
•Barometric pressure correction:Preset within the range 500 to 800 mm Hg

ABB

Aerated DO ABB

Dissolved Oxygen (Trace)

•Sensor works drift-free and reliably and can be calibrated during a measurement.
•Response time is extremely short.
•Small oxygen peaks can be detected.
•Rugged design allows for long maintenance intervals.
•Sensor can easily be cleaned.
•Sensitivity can be checked at any time without interrupting the measurement.

Trace Oxygen Dr Thiedig

Fluoride

  • Ion Selective Electrode (ISE)
    • Range: 0.02-1/10/100 mg/L as Fluoride
    • One isolated recorder output, 4-20 mA
    • Enclosure – IP55
  • Automatic Calibration

SYSTEA

Hardness

  • Measuring Principal: Colorimetric, Mg/EDTA, Calmagite
  • Measuring Time of 10-12 minutes
  • Measuring Range of 0-1 up to 50°F, other ranges available on request
  • 4-20 mA output
  • IP55 Protection
  • Integrated keyboard and graphics display, RS232 option
  • Dimension :800x450x300 mm (hxwxd)

SYSTEA

Ca-Mg

•High reliability achieved with a new measuring vessel and its associated fiber optics system
•Low cost of ownership : reduced reagents’ consumption, simple  maintenance
•Ergonomic design
•JBUS RS232 communication protocole (RS485 on option)
•Journal of events and integrated data logger
•Data retrieval via USB key : text files with Excel spreadsheet compatibility

SERES Ca-Mg

Nitrate

• Measuring Principle: Colorimetric,Hydrazine reduction
• Range 0-5/10/20/100/200/1000 ppm N-NO3
• Output Signal 4-20 mA
• IP55 Protection
• Programmable photometer
• Automatic calibration / validation / cleaning

• Easy installation and operation

SYSTEA

Nitrite

  • Measuring Priciple: Colorimetric, NED/SAAN method
  • Measuring time of 5 to 8 minutes depending on the range
  • Measuring Range: 0-0.2/0.7/2/5/10/20/100/200 ppm N-NO2
  • Output 4-20 mA signal
  • IP55 Protection
  •  Integrated keyboard and graphics display, RS232 option
  • Dimension: 800x450x300 mm(hxwxd)

SYSTEA

Oil in Water

  • Compact system, fast & efficient
  • IR light scattering detection,
  • automatic, on line
  • Intuitive, touchscreen user interface
  • Extended choice of inputs & outputs
  • Easy, cost-efficient operation
  • No reagent, no cleaning product
  • Automatic cleaning of measuring vessel

SERES

Phosphate

• Colorimeteric , Molybdate ascorbic acid method
• Range: 0-0.2/0.7/2/5/10/20/100/200 ppm P-PO4
• Output 4-20 mA
• IP55
• Grab samples facility available. Pumpless system
• Low Reagent Consumption And Pressurized Reagent Delivery System Reduce Maintenance Requirements
• Three Choices for Calibration, Including Programmable Auto Calibration

ABB

SYSTEA

Silica

• Colorimeteric Measuring Method
• Range: 0 to 5000 ppb SiO2, minimum range 0 to 50 ppb
• Grab samples Facility Available.
• Low Reagent Consumption , Reduce Maintenance Requirements
• Fast, accurate and reliable
• Easy to use

ABB

Dr Thiedig

Sodium

• Multi-stream measurement capability
• Range 0.01 to 10,000 ppb, μg/l, μg/kg
• Pumpless liquid handling section
• Automatic calibration
• Automatic reactivation ensures optimum response time and performance
• Easy to operate and maintain with automatic calibration

ABB

Silt Density Index (SDI)

• Standard 25 mm test filters.
• Analog & Relay Outputs.
• Complies with ASTM D4189-95
• Data Logging
• Available In 4 Channels
• Withstands Do Feed Pressure-1500 psi

POTENCE

Total Organic Carbon (TOC)

• Batch analysis and Programmable frequency
• Patented Stop – Flow Oxidation Technology
• Range from 0-20 mg/l up to 1000 mg/l
• 4-20 mA Output
• IP55, RS232 option
• Accurate Measurement Independent of Flow Rate,Pressure or Temperature
• Highly Reliable, Rugged, All – Metal Design
• Multi channel Configurable

SYSTEA

Total Suspended Solid (TSS)

• Single/dual  Channel Suspended Solids Analyzer
• Unique system that combines advanced electronics with a solid-state optical          sensor
• Sensor utilizes optical principals based on the near infrared (880nm) range.
• Sensor is designed to measure the solids concentrations in biological reactors,        open RAS or WAS channels, and clarifier influent channels

INSITE IG 3150

INSITE IG 1500

Turbidity

• Automatic sensor cleaning
• Range 0…100 to 0…1000 FTU and 0…2000 mg/l
• Choice of flow-through and dip turbidity systems
• Available with Self-cleaning Sample Chamber Option
• Simple to calibrate

GF

ABB 4690

ABB 4670

We are offering solution for the liquid analysis of other parameters like –

ALKALINITY COD (PERMANGANATE/ DICHROMATE) MANGANESE
ALUMINUM COLOR NICKEL
ARSENIC COPPER PHENOL
BORON CYANIDE SILICATES
CADMIUM HYDRAZINE SUCROSE
CALCIUM IRON SULFATE
CHROMIUM LEAD SULFIDE